Eddy Current Loss Heating
Theory: heat from unwanted eddy currents
Overview
Induction heating uses eddy currents on purpose, so why do transformers avoid them?
Same mechanism, opposite goal. Changing flux through a conductor drives eddy currents around it, which heat it through resistance. Induction heating wants that, but in transformer and motor cores the only job is carrying flux, so eddy heat is pure loss, lowering efficiency and raising temperature. Cores are therefore stacks of thin insulated steel sheets that narrow eddy paths. Meanwhile flux leaking out of the core hits thick steel such as tank walls and fittings, concentrating eddy currents at the surface and creating local hot spots. Both are coupled problems: obtain loss distribution from the field and pass it to thermal analysis.
Lamination eddy loss and skin depth
f is frequency, B_p peak flux density (1.5 T), d sheet thickness, ρ resistivity (0.5 μΩm for silicon steel) and μ permeability (relative 3000). The formula holds when thickness is well below skin depth δ.
Surface loss in thick steel
H_p is peak tangential field at the surface. Magnetic saturation usually makes real loss larger, so treat this as a lower-bound guide.
Adding silicon to iron
Around 1900 Hadfield in Britain found that adding a few per cent of silicon to iron raised its resistivity several-fold while keeping good magnetic properties. Higher resistivity means weaker eddy currents. Cores of thin, stacked silicon-steel sheets became the standard for transformers and motors, and core-material development still pursues higher resistivity, thinner sheets and easier flux passage.
Worked examples
Example 1: eddy loss by thickness and frequency (1.5 T)
| Thickness | 50 Hz | Thickness/skin depth at 50 Hz | 400 Hz | Thickness/skin depth at 400 Hz |
|---|---|---|---|---|
| 0.20 mm | 0.097 W/kg | 0.22 | 6.19 W/kg | 0.62 |
| 0.35 mm | 0.296 W/kg | 0.38 | 19.0 W/kg (rough) | 1.08 |
| 0.50 mm | 0.605 W/kg | 0.54 | 38.7 W/kg (rough) | 1.54 |
| 1.0 mm | 2.42 W/kg (rough) | 1.09 | 155 W/kg (rough) | 3.08 |
Skin depth is 0.92 mm at 50 Hz and 0.32 mm at 400 Hz. Entries with thickness/skin depth near or above 1 are outside the simple formula's range; actual loss is lower because flux doesn't penetrate fully. Real sheet loss also includes hysteresis and other components.
Example 2: wall hit by leakage flux (5 kA/m peak, 50 Hz)
| Material | Skin depth | Surface loss | Rise in oil (h = 50 W/m²K) |
|---|---|---|---|
| Mild steel (0.15 μΩm, μr 500) | 1.23 mm | 1,521 W/m² | 30.4 K |
| Aluminium shield (0.028 μΩm) | 11.9 mm | 29 W/m² | 0.6 K |
Aluminium conducts better than steel, so why is its loss about one-fiftieth?
Because it isn't magnetic. Steel's relative permeability is in the hundreds, so flux is squeezed into the outer millimetre or so and current crowds there; a thinner current layer means more resistance and more loss. Non-magnetic aluminium spreads current over about 12 mm and has lower resistivity. Loss scales with ρ/δ: steel's 0.15 μΩm/1.23 mm against aluminium's 0.028 μΩm/11.9 mm is about 1:50. Transformers therefore line tanks with aluminium or copper to repel leakage flux, or conversely use laminated steel magnetic shunts to absorb it and guide it along low-loss paths. Which works better depends on leakage-flux direction and magnitude, so 3D field analysis gives loss distribution and thermal analysis checks hot-spot temperatures.
Modelling workflow
- Give sheet losses from measured data versus frequency and flux density.
- Solve the field including core, windings and surrounding structures.
- Treat thick steel with mesh finer than skin depth or a surface-impedance condition.
- Pass loss distribution to thermal analysis with cooling to get temperature.
- If resistivity changes with temperature, re-solve the field until converged.
“Tank bolts with scorched paint”
During a routine inspection of a large transformer, paint was discoloured only around the bolts fastening the tank cover. 3D field analysis showed that near a high-current bushing, the cover plate and bolts formed a closed loop in which leakage flux induced current. Replacing part of the cover with non-magnetic stainless steel broke the loop; the predicted temperature fell, and the next inspection found no discolouration.
Common mistakes
Mistakes and fixes
| Mistake | Effect | Fix |
|---|---|---|
| Simple formula at high frequency | Loss overestimated | Check skin depth |
| Eddy loss as total core loss | Core loss underestimated | Measured core-loss data |
| Coarse mesh in thick steel | Surface loss wrong | Finer than skin depth |
| Omitting structures | Local hot spots missed | Include fittings and bolts |
| Ignoring saturation | Surface loss underestimated | Nonlinear magnetisation |
I'd like to learn related topics.